<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15065</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: Trailing edge clamp actuator bar cylinder error, both sensors activated
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_3244</Text></ListItem>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Reports this error if both extended and retracted tec sensors indicate
true after a tec backbone is lowered and a time of te_delay has expired.
Only reported if te sensors enabled.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Check that TEC magnets are lined up, this error will occur if the tec
backbone is unable to go all the way down when it tries to retrieve the
tec magnetic clamps.
</text></DescriptionText>
<DescriptionText><text>
Otherwise call Creo service
</text></DescriptionText>
</OperatorAction>
<Cause>
sensor or wire failure or TEC Lock failing to unlock or magnets or other
obstruction preventing the TEC backbone from going all the way down.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/al_cal_nte.xml</LinkAddress><LinkTitle>NVS: al nte</LinkTitle></Link>
NVS: aldly te cal
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:50 2008 PST
</Updated>
<Links>
</Links>
</Error>